NHBC chapter 5.4

New NHBC Basement Standard – 5.4 Waterproofing of Basements and Other Below Ground Structures.

Last week NHBC released one of their periodic ‘Technical Extra’ publications, and this edition exclusively deals with the waterproofing of basements and other below ground structures.

As I understand it NHBC have approximately 80% of the structural warranty insurance market, and so they have felt the effects of basement waterproofing failures more than any other.  More specifically, since 2005/6 they have spent within the region of £21m on remedial basement waterproofing.As a result NHBC started a basement campaign in 2013 to highlight the issue, with this including the drafting of a new basement standard – ‘5.4 Waterproofing of Basements and Other Below Ground Structures’. This was released last week along with the Technical Extra!

I said that times were changing a month or two ago, and here we are.

NHBC are promoting an approach to waterproofing design and installation which falls broadly into line with the guidance detailed within British Standard 8102 (2009) Code of practice for the protection of below ground structures against water from the ground, which advises design by specialist waterproofing designers, and specifications driven by an assessment of risk, primarily relating to site conditions and structure – could not agree more.

To NHBC’s credit however, they have pushed even further with specific requirements which will greatly assist in reducing problem basement waterproofing systems.

Firstly they are stating that installation should be by trained, qualified operatives.  This will address the historic situation where tanking products were sold through building merchants, with general contractors/ground workers picking these up and then using untrained labour to install.  You can bet that some of the product manufacturers (selling into merchants) are not pleased with this, but no doubt it will lessen failures.

Another example relates to the use of ‘combined protection’, which is a section within BS8102 (section 6.2.2), advising that where site conditions are aggressive (very wet) or the consequences of failure are dire – (generally the case within habitable basements representing the majority of NHBC’s insured property) – that two forms of waterproofing system be employed to provide suitably low risk levels.

Within the new standard ‘combined protection’ is stipulated for habitable space, wherever the retained earth is greater than 600mm depth, unless there is long term monitoring of site via bore holes, i.e. for more than one year, suitable number of holes and checks at min. 3 month intervals, indicating that water table is permanently below basement slab level.  In which case they will accept a Type B integrally waterproof structure.  Wow.

In addition, they state that for grade 2 environment (no water penetration acceptable, same as grade 3) and anything with retained earth greater than 600mm, tanking membranes which aren’t fully bonded, cannot be used in isolation.  This is again significant because it prevents the use of external adhesive sheet membrane tanking systems in isolation, and based on statistics from the basement campaign presentation, tanking generally has provided NHBC with a greater number of claims (66%) versus the other forms of waterproofing.  I personally see more issues with external tanking membranes than any other form of waterproofing.

In any case, the main factor is that beyond 600mm, they will not generally accept anything other than combined protection, unless the site is essentially assumed to be dry based on long term site investigation.  I have thoughts on such assumptions which you can read about here.

We would wholeheartedly agree with this approach.  We recommend combined systems and design these in an efficient manner, providing super low risk levels without going down the route of what I call ‘kitchen sink waterproofing’, where manufacturers seem to throw everything but.. at the design…  (Blog post to follow on this subject).

In any case, credit to NHBC for raising standards, there are some tweaks that could be implemented to improve 5.4, but it is still a substantial leap forwards.

I’d like to think that NHBC were spurred on by the updated Premier Guarantees technical manual that we developed, but then maybe it had something to do with having spent £21m on leaky basements…

Also, credit to the Property Care Association and to Newton Waterproofing for their role in pushing this forward.

J

Update: NHBC video on the their new standard:

2 thoughts on “New NHBC Basement Standard – 5.4 Waterproofing of Basements and Other Below Ground Structures.”

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google photo

You are commenting using your Google account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s